Su proyecto de seguridad necesita cables con doble protección anti-humedad (cinta “waterblock” + cobre estañado para evitar la corrosión)? Un ejemplo de esta familia 8237_techdata
Características Físicas (Generales)
Conductor
| AWG | Stranding | Material | Nominal Diameter | No. of Coax |
|---|---|---|---|---|
| 13 | 7x21 | BC - Bare Copper | 0.085 in | 1 |
| Conductor Count: | 1 |
Insulation
| Material | Nominal Diameter |
|---|---|
| PE - Polyethylene | 0.285 in |
Outer Shield Material
| Type | Material | Coverage [%] |
|---|---|---|
| Braid | BC - Bare Copper | 95 % |
Outer Jacket Material
| Material | Nominal Diameter |
|---|---|
| PVC - Polyvinyl Chloride | 0.403 in |
Electrical Characteristics
Conductor DCR
| Nominal Conductor DCR | Nominal Outer Shield DCR | Outer Conductor DCR |
|---|---|---|
| 1.9 Ohm/1000ft | 1.2 Ohm/1000ft | 1.2 Ohm/1000ft |
Capacitance
| Nom. Capacitance Conductor to Shield |
|---|
| 28.5 pF/ft |
Inductance
| Nominal Inductance |
|---|
| 0.079 µH/ft |
Impedance
| Nominal Characteristic Impedance |
|---|
| 50 Ohm |
High Frequency (Nominal/Typical)
| Frequency [MHz] | Nom. Insertion Loss |
|---|---|
| 1 MHz | 0.2 dB/100ft |
| 10 MHz | 0.6 dB/100ft |
| 50 MHz | 1.3 dB/100ft |
| 100 MHz | 1.9 dB/100ft |
| 200 MHz | 2.8 dB/100ft |
| 400 MHz | 4.2 dB/100ft |
| 700 MHz | 5.9 dB/100ft |
| 900 MHz | 6.9 dB/100ft |
| 1000 MHz | 7.4 dB/100ft |
| 4000 MHz | 23.2 dB/100ft |
Delay
| Nominal Delay | Nominal Velocity of Propagation (VP) [%] |
|---|---|
| 1.54 ns/ft | 66 % |
Power Rating
| Frequency [MHz] | Max. Power Rating [W] | Nominal Power Rating [W] |
|---|---|---|
| 50 MHz | 1,200 W | 1,200 W |
| 100 MHz | 800 W | 800 W |
| 400 MHz | 320 W | 320 W |
| 1,000 MHz | 180 W | 180 W |
Voltage
| Non-UL Voltage Rating |
|---|
| 3700 V RMS |
Temperature Range
| UL Temp Rating: | 75°C |
| Operating Temp Range: | -40°C To +75°C |
Mechanical Characteristics
| Bulk Cable Weight: | 102 lbs/1000ft |
| Max Recommended Pulling Tension: | 190 lbs |
| Min Bend Radius/Minor Axis: | 4.25 in |
Standards
| NEC/(UL) Specification: | CMH |
| CEC/C(UL) Specification: | CMH |
| CPR Euroclass: | Eca |
| RG Type: | 8/U Type |
Applicable Environmental and Other Programs
| EU Directive 2000/53/EC (ELV): | Yes |
| EU Directive 2003/96/EC (BFR): | Yes |
| EU Directive 2011/65/EU (ROHS II): | Yes |
| EU Directive 2012/19/EU (WEEE): | Yes |
| EU Directive Compliance: | EU Directive 2003/11/EC (BFR) |
| EU CE Mark: | No |
| EU RoHS Compliance Date (yyyy-mm-dd): | 2004-01-01 |
| CA Prop 65 (CJ for Wire & Cable): | Yes |
| MII Order #39 (China RoHS): | Yes |
Suitability
| Suitability - Aerial: | Yes - Black only, when supported by messenger wire |
| Suitability - Burial: | No |
| Suitability - Hazardous Locations: | No |
| Suitability - Indoor: | Yes |
| Suitability - Outdoor: | Yes - Black only |
Flammability, LS0H, Toxicity Testing
| ISO/IEC Flammability: | IEC 60332-1-2 |
Plenum/Non-Plenum
| Plenum (Y/N): | No |
Part Number
Variants
| Item # | Color | UPC | Length | Footnote |
|---|---|---|---|---|
| 8237 010100 | Black | 612825196693 | 100 ft | C |
| 8237 0101000 | Black | 612825196709 | 1,000 ft | C |
| 8237 010500 | Black | 612825355625 | 500 ft | C |
| Footnote: | C - CRATE REEL PUT-UP. |
History
| Update and Revision: | Revision Number: 0.274 Revision Date: 08-22-2019 |