cable osp

Cable OSP de categoría 6A, 4 pares, F/UTP, sin gel

Cable horizontal de categoría 6A para instalaciones, con clasificación OSP, 4 pares, conductores de cobre sólido desnudo de 23 AWG, F/UTP - apantallado, sin gel

OSP-Planta Exterior, Cable Horizontal de Premisa, Ethernet hasta 10GBASE-T, Wi-Fi 6, Wi-Fi 5, PoE++, PoE+, PoE, Enivronamientos Ruidosos, HDBaseT, Cámaras IP

Construction Details

CONDUCTOR

Tamaño TipoMaterialNumero de pares
23SolidoBC - Cobre 4

INSULATION

MaterialCódigo de Color
PO - PolioelefinaBlanco & Azul, Blanco & Naranja, Blanco & Verde, Blanco & Café

OUTER SHIELD

Tipo de cubiertaMaterialCubierta Tipo de Cable
TapeBi-Laminado (Alum+Poly)100%26 AWG (7x34) TC

OUTER JACKET

SeparadorMaterial DiámetroRipcord
Center Member (Patented T-Spline®), EquiBlock™ Barrier TechnologyPO - Polyolefin0.29 in (7.4 mm)Si
Diametro de Cable General (Nominal)0.29 in (7.4 mm)

Electrical Characteristics

ELECTRICALS

Max. Conductor DCRMax. Capacitance Unbalance
82 Ohm/km (25 Ohm/1000ft)45 pF/100m

DELAY

FrequencyMax. DelayMax. Delay SkewNom. Velocity of Prop.
100 MHz537.6 ns/100m45 ns/100m68%

HIGH FREQUENCY

Frequency [MHz]Max. Insertion Loss (Attenuation) [dB/100m]Min. NEXT [dB]Min. PSNEXT [dB]Min. ACR [dB]Min. PSACR [dB]Min. ACRF (ELFEXT) [dB]Min. PSACRF (PSELFEXT) [dB]Min. RL (Return Loss) [dB]Max./Min. Input Impedance (unFitted)Max./Min. Fitted ImpedanceMin. PSANEXT [dB]Min. PSAACRF [dB]Min. TCL [dB]Min. ELTCTL [dB]
12.174.372.372.270.267.864.820.0105 +/- 10115 +/- 1567.067.040.035.0
43.865.363.361.559.555.852.823.0105 +/- 10100 +/- 767.066.240.023.0
85.360.858.855.453.449.746.724.5100 +/- 22100 +/- 767.060.140.016.9
105.959.357.353.451.447.844.825.0100 +/- 22100 +/- 767.058.240.015.0
167.556.254.248.846.843.740.725.0100 +/- 22100 +/- 767.054.138.010.9
208.454.852.846.444.441.838.825.0100 +/- 22100 +/- 767.052.237.09.0
259.453.351.344.042.039.836.824.3100 +/- 22100 +/- 767.050.236.07.0
31.2510.551.949.941.439.437.934.923.6100 +/- 22100 +/- 767.048.335.15.1
62.515.047.445.432.430.431.928.921.5100 +/- 22100 +/- 765.642.332.0
10019.144.342.325.223.227.824.820.1100 +/- 22100 +/- 762.538.230.0
20027.639.837.812.210.221.818.818.0100 +/- 22100 +/- 758.032.227.0
25031.138.336.37.35.319.816.817.3100 +/- 32100 +/- 756.530.226.0
30034.337.135.12.90.918.315.316.8100 +/- 32100 +/- 755.328.725.2
35037.236.134.116.913.916.3100 +/- 32100 +/- 754.327.324.6
40040.135.333.315.812.815.9100 +/- 32100 +/- 753.526.224.0
45042.734.532.514.711.715.5100 +/- 32100 +/- 752.725.123.5
50045.333.831.813.810.815.2100 +/- 32100 +/- 752.024.223.0

VOLTAGE

Voltage Rating
300 V

Mechanical Characteristics

TEMPERATURE

OperatingInstallationStorage
-20°C To +70°C0°C To +60°C-40°C To +75°C

BEND RADIUS

Installation Min.
2.9 in (74 mm)
Max. Pull Tension25 lbs (11 kg)
Bulk Cable Weight33 lbs/1000ft (49 kg/km)

Standards and Compliance

Environmental SuitabilityOutdoor - Water Exposure, Outdoor
IEEE ComplianceIEEE 802.3bt Type 1, Type 2, Type 3, Type 4
Data CategoryCategory 6A
TIA/EIA ComplianceANSI/TIA-568.2-D Category 6A
ISO/IEC Compliance11801 ed 2.2 (2011) Class EA
CENELEC ComplianceSegregation class according EN50174-2 = a

Product Notes

NotesElectrical values are expected performance based on cable testing and representative performance within a typical Belden system. Print Includes Descending Footage/Meter Markings from Max. Put-Up Length to 0. Not Suitable for Direct Burial. Cable jacket system is specially designed to protect cable core. Cable contains no water-blocking tapes, gels, or powders. Install in accordance with all applicable electrical codes. Maintain jacket integrity throughout installation process. Do not allow water or fluids to penetrate jacket sheath or to enter ends of cable. Ensure ends of cable will be protected from water/fluids after installation. Belden recommends using an entrance demarcation point when transitioning inside buildings with OSP cables. The suggested transition point is the REVConnect core coupler, part number RVACPKUBK-S1.

History

Update and RevisionRevision Number: 0.15 Revision Date: 11-01-2022

Hide Specifications

Part Numbers

Item #ColorPutup TypeLength
DOSP6AF 0101000BlackReel1,000 ft
Cable OSP CAT 6A
Karina Romera Scott April 11, 2025
Share this post
Tags
Archive